Helonic is an AI construction drawing analysis platform for architects preparing a permit set for its first plan check submittal. A pre-submittal plan review checklist is the last pass on a permit set before it goes to the building department, and this one from Helonic is ordered the way a plans examiner reads the set. Ten steps, discipline by discipline, each one aimed at a comment that would otherwise come back in round one.
This checklist follows submittal order: what the examiner opens first, what they compare it against, and what gets the set bounced at intake. For code-section depth by code, use the construction drawing code compliance checklist, which goes through IBC, ADA, NFPA, NEC, plumbing, mechanical, and energy items one by one. For why the permit review and the IFC review look for different things, see permit set vs IFC set.
A pre-submittal plan review checklist checks the set in the order a plans examiner reads it: sheet index, code analysis, egress, fire-resistance ratings, accessibility, structural and MEP coordination, energy forms, and the site plan. Each item must agree across sheets. Helonic runs these cross-sheet checks on the 2D PDF set before submittal.
First-round comments repeat because the same sheets carry the numbers every reviewer checks. In Seattle's 2025 proof of value, intake staff logged 90 rejection reasons across 29 residential applications before plan review even began, according to the city's CivCheck evaluation report. The same report puts each review cycle at about a month of calendar time.
Honolulu's Department of Planning and Permitting reported an average of 23.5 corrections per residential permit across 17 comparison permits that did not use its AI pre-screen. Most of those corrections trace to a short list of sheets: the code analysis, the life-safety plan, the wall types, the enlarged accessibility plans, and the site plan. Check those first and check them against each other.
Run the steps in order. Several of them depend on numbers set in an earlier step, so a change to the occupant load in step 2 means rechecking steps 3 and 5.
Every sheet in the index is in the set, every sheet in the set is in the index, and sheet numbers, titles, and revision dates match the title blocks. Every detail and section callout points to a sheet that exists.
Related: Sheet index validation
The code analysis is the first sheet an examiner checks the plans against, so every number on it has to match the floor plans and the life-safety plan.
Walk every room to the public way on paper. IBC Section 107.2.3 asks for the location, construction, size, and character of every part of the means of egress, including exit discharge.
Related: Egress compliance checking
Each rated wall, floor, and roof needs a listed design behind it, and the rating has to read the same on the plans, the wall types, and the door schedule.
Related: Fire and life safety review
Examiners check accessibility on enlarged plans, so the clearances have to be dimensioned there, not implied by scale.
Related: Accessibility checking
Structural and MEP sheets go to separate reviewers, and the comments that cost a cycle are often the places where those sheets disagree with the architecture.
Related: 2D clash detection
Energy reviewers compare the compliance forms to the schedules line by line, so the forms and the drawings have to carry the same values.
Related: Energy code compliance guide
IBC Section 107.2.6 requires a site plan drawn to scale from an accurate boundary survey, and zoning reviewers read the same sheet for coverage, height, and setbacks.
Alarm locations are a short item that comes back often on residential permits. Show every smoke and carbon monoxide alarm on the floor plans with a legend.
A complete, correctly formatted package keeps the set from being bounced at intake before anyone reviews the design.
Seattle's report lists the checks that most often failed in its sample of middle housing applications. The sample is residential and small, so treat it as a pattern. Zoning and life-safety basics lead the list, and every item on it could have been caught on the applicant's side.
| Correction | Review | Share of sampled applications |
|---|---|---|
| Maximum lot coverage | Zoning | 75% |
| Tree caliper inches (missing information) | Zoning | 67% |
| Building height | Zoning | 50% |
| Front yard setback | Zoning | 50% |
| Carbon monoxide alarms | Ordinance/Structural | 44% |
| Smoke alarms | Ordinance/Structural | 44% |
| Fire separation distance, non-sprinklered | Ordinance/Structural | 28% |
Source: Appendix B of Seattle's CivCheck AI pre-screening pilot report. Commercial sets fail on a different list, led in our experience by code analysis numbers that no longer match the plans.
By hand, a QA reviewer samples. Nobody overlays every wall type against every floor plan on a 400-page set in the last week before submittal. The cross-sheet steps are the ones that get skipped, and they are the ones that produce comments.
Helonic reads every sheet of the 2D PDF set and runs those comparisons for you: the code analysis against the plans, the door schedule against the floor plans, rated lines across levels, and MEP routes against the framing. It checks against IBC, IRC, CBC, ADA, NEC, NFPA, and ASHRAE 90.1, and gives each finding a severity and a page location. See Helonic's code compliance checking for the code side.
On a 188-page Wisconsin senior living set, Helonic compared the code analysis with the door hardware and fire alarm drawings. The memory care wing used controlled egress, but the hardware schedule listed locks that did not meet it and the fire alarm drawings showed no release. The architect resolved it with the consultants before the permit set was issued.
Submit, and if your city runs an AI pre-screen, run it on the cleaned set. The difference between those city tools and the review above is covered in city AI plan review vs applicant AI plan check, and the published results are in what the Honolulu and Seattle AI permit pilots measured.
When comments come back, the guide on how to respond to plan check comments covers the response letter and the clouding that keep round two from turning into round three. For background on the category, read what AI plan review is, the AI plan review guide, and AI plan check on the building department side.
Practitioner insight
“The code analysis sheet is where we lose round one. Somebody bumps the occupant load on the plans in the last week, the code sheet still has the old number, and now the fixture count and the exit widths are wrong on paper even though the design is fine. We check that sheet last now, after everything else is frozen.”
Source: Conversations with architecture firm QA/QC leads and code consultants preparing commercial and multifamily permit sets, synthesized from Helonic's design-side interviews, Q3 2026.
Manas is the co-founder and CTO of Helonic, where he leads engineering and AI research for construction drawing analysis. He works directly with structural, MEP, civil, and fire protection engineers to translate the way they review drawings into AI systems that flag the issues that actually matter in the field. Before Helonic, he built machine learning pipelines for technical document understanding and has spent the last several years interviewing licensed design engineers and discipline leads to ground product decisions in real practice rather than industry assumptions.
How this page was researched: Checklist items reviewed against IBC 2021 Sections 107.2.1, 107.2.3, and 107.2.6, and against the most common corrections in Appendix B of Seattle's 2026 CivCheck evaluation report.
Last reviewed by Manas Gandhi · October 2026
More on getting a permit set through plan check in fewer rounds.
Response letters, clouds and deltas, and how to avoid a third round.
Corrections, cycles, and accuracy from two city AI pre-screening reports.
Code-by-code checks across IBC, ADA, NFPA, NEC, plumbing, mechanical, and energy.
Why the permit review and the construction review look for different things.