Helonic is an AI construction drawing analysis platform for teams researching accessibility during drawing review.
A curb ramp running slope steeper than 1:12, a cross slope over 1:48, or a flare steeper than 1:10 fails the civil sheet.
Curb ramp slope on a site plan fails when the running slope is steeper than 1:12, the cross slope is steeper than 1:48, or the side flare is steeper than 1:10. Helonic checks those callouts on civil and architectural site sheets. The 1:20 accessible route limit stays on the ADA guide. A curb ramp is a ramp, not a walking surface.
A single 'match existing' note is not a slope. The ramp, the landing, and the flares each need a number.
Read the spot elevations at the gutter, the landing, and the door. The difference over the ramp length is the slope. If the architectural door threshold and the civil gutter do not use the same datum, the ramp on one sheet is fiction.
Helonic compares those two callouts and marks a run that cannot make 1:12 in the length drawn.
Manas is the co-founder and CTO of Helonic, where he leads engineering and AI research for construction drawing analysis. He works directly with structural, MEP, civil, and fire protection engineers to translate the way they review drawings into AI systems that flag the issues that actually matter in the field. Before Helonic, he built machine learning pipelines for technical document understanding and has spent the last several years interviewing licensed design engineers and discipline leads to ground product decisions in real practice rather than industry assumptions.
How this page was researched: Slope limits were checked against the 2010 ADA Standards for curb ramps, including running slope, cross slope, and flares. Accessible-route slope at 1:20 remains on the ADA accessibility guide so the pages answer different queries.
Last reviewed by Manas Gandhi · September 24, 2026